MATERIAL SAFETY DATA SHEET (MSDS)
QP-350 Omni Cleaner Plus'''

Revision: 0 Date:01/31/97

Degree of Hazard
4 - Severe
3 - Serious
2 - Moderate
1 - Slight
0 - Minimal


HAZARDOUS INGREDIENTS / OSHA PEL/ ACGIH TLV/ PERCENTAGE / CAS NUMBER

None

*Does not contain SARA Section 313 Reportable compounds
PHYSICAL AND CHEMICAL CHARACTERISTICS
Boilong point: 212 deg F
Specific Gravity: 1.01
Vapor Pressure: No Data
Solubility in Water: Complete
Reactivity in Water: None
Melting Point: 28 deg F
pH (as is): 9.5
Appearance and Odor: Clear, blue liquid, pleasant odor
FIRE & EXPLOSION DATA


Flash Point: >212 deg F
Method Used: TAG Closed Cup (TCC) ASTM D56
Auto-Ignition Temperature: No data
Flammable Limits Upper: No data
Air Lower: No data
Extinguisher Media: Carbon dioxide, chemical foam, water fog
Special Fire Fighting Procedures: Do not enter confined space without a self-contained breathing apparatus
Unusual Fire and Explosion Hazards: None Known

 

MATERIAL SAFETY DATA SHEET
QP-550 Omni Cleaner Plus''" Page 2
Revision: 0
DATE: 01-31-97

Physical Hazards (Reactivity Data)
Stability: Stable. Avoid temperature extremes.
Incompatability; Avoid strong oxidizers, acids.
Hazardous Decomposition Products: Oxides of Carbon and Nitrogen on combustion
Hazardous Polymerization: Will not occur

HEALTH HAZARDS
Acute: May be irritating to skin and eyes
Chronic: None expected at industrial use levels when good personal hygiene practices are followed.
Chemical Carcinogen: National Toxicology Program: NO
I.A.R.C. Monographhs: NO
OSHA: NO

SIGNS & SYMPTOMS OF EXPOSURE / ROUTES OF ENTRY
Eyes: Can cause irritation, burning, and redness.
Skin: Brief contact should not produce harmful effects. Prolonged contact will cause irritation and burning
Inhalation: In concentrated form may cause headache, dizziness, nausea, and irritation of respiratory tract.
Ingestion: Can cause nausea, vomiting, diarrhea.

FIRST AID PROCEDURES
Eyes: Wash eyes with large amounts of water for at least 15 minutes occasionally lifting upper and lower lids. Get medical attention.
Skin: Wash contaminated skin with soap and large amounts of water then rinse with dilluted vinegar. Remove clothing and footwear and wash before reuse.
Inhalation: Remove to fresh air - administer oxygen if necessary. If symptoms persist, get medical attention.
Ingestion: Do not induce vomiting. If victim is concious give 2 glasses of milk or water with diluted vinegar or fruit juice. Seek medical assistance.


MATERIAL SAFETY DATA SHEET

QF-550 Omni Clean PIusTM

Revision: 0


DATE:01-31-97


SPECIAL PRECAUTIQNS AND SPILL/LEAK PROCEDURES
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE:

Wear eye protection, launder contaminated clothing before reuse- Store drums is a cool place., bung up, and closed tightly-

OTHER PRECAUTIONS:
Have eye wash station, safety shower and washing facilities available.

STEPS TO BE TAKEN IN CASE MATERIAL 1S RELEASED OR SPILLED:
Contain the spills and leak to prevent discharge to the environment. Neutralize catiously with a base such as soda ash.

WASTE DISPOSAL METHODS:
First consult federal, state, and local regulations- If material t be salvaged, may be incinerated

A HAZARDOUS WASTE CODE: None


SPECIAL PROTECTION INFORMATION/CONTROL MEASURES

Respiratory Protection: For exposure to airborne mist use NIOSH/OSHA gas respirator.
Ventilation: Adequate - local exhaust
Protective Gloves: Rubber or neoprene
Eye Protection: Saftey glasses with side shields but recommend use of chemical splash goggles instead.
Other Protective Clothing or Equipment: Wear imprevious clothing to prevent skin contact. Wash hands with soap and water after handling.

PERSONAL PROTECTION CODE
Personal Protection
Code "A" Safety glasses

TRANSPORTATION DATA
DOMESTIC (D.O.T.)
Proper shipping Name: Compound Cleaning Compound (not regulated)
Hazard Class: None
UN: NONE
Labels: None



 
 


 
 

  

 
 

Alfa Medical  59 Madison Ave, Hempstead, NY 11550 
1-800-748-1259 fax 516-489-9364
International Calls 516-489-3855